• 首页期刊简介编委会刊物订阅专栏专刊电子刊学术动态联系我们English
引用本文:邹晓华,王双虎,胡国新,周云芳.UPLC-MS/MS快速测定大鼠血浆中的氯沙坦及其代谢产物[J].中国现代应用药学,2014,31(6):727-731.
ZOU Xiaohua,WANG Shuanghu,HU Guoxin,ZHOU Yunfang.Rapid Determination of Losartan and Its Metabolite by UPLC-MS/MS[J].Chin J Mod Appl Pharm(中国现代应用药学),2014,31(6):727-731.
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 2478次   下载 1898 本文二维码信息
码上扫一扫!
分享到: 微信 更多
UPLC-MS/MS快速测定大鼠血浆中的氯沙坦及其代谢产物
邹晓华1, 王双虎2, 胡国新3, 周云芳2
1.丽水市第二人民医院药剂科,浙江 丽水 323000;2.丽水市人民医院临床药学实验室,浙江 丽水 323000;3.浙江省温州医科大学药学院药理教研室,浙江 温州 325000
摘要:
目的 建立快速测定大鼠体内氯沙坦及其代谢产物(E-3174)浓度的UPLC-MS/MS方法。方法 Waters XEVO TQD三重四级杆液质联用仪, 色谱柱为ACQUITY UPLC? BEH C18柱(100 mm ×2.1 mm,1.7 μm);流动相为乙腈-水(含0.1%甲酸和0.5%氨水)(60∶40),流速为0.2 mL·min-1,柱温30 ℃,内标为地西泮;质谱条件:电喷雾离子化源(ESI),正离子检测模式;加入200 μL乙腈沉淀蛋白,13 000 r·min-1离心10 min转移至1.5 mL EP管中取2 μL上样。结果 E-3174的保留时间为1.54 min,线性范围为6.25~800 ng·mL-1(r=0.999 8),最低定量限为0.5 ng·mL-1,回收率为96.6%~98.37%;氯沙坦的保留时间为1.38 min,线性范围为12.5~1 600 ng·mL-1(r=0.999 6),最低定量限为1.0 ng·mL-1,回收率为98.4%~100.6%。两者的日内、日间RSD均<5%,孵育体系中的其他内源性物质不干扰测定。结论 该方法操作简便,重复性好,适于快速测定大鼠体内氯沙坦及其代谢产物浓度。
关键词:  CYP2C9  氯沙坦  药动学  高效液相色谱-质谱法
DOI:
分类号:
基金项目:卫生部行业科研专项经费项目(201302008)
Rapid Determination of Losartan and Its Metabolite by UPLC-MS/MS
ZOU Xiaohua1, WANG Shuanghu2, HU Guoxin3, ZHOU Yunfang2
1.Department of Pharmacy, the Second People's Hospital of Lishui City, Lishui 323000, China;2.The Laboratory of Clinical Pharmacy, People's Hospital of Lishui City, Lishui 323000, China;3.Department of Pharmacology, Wenzhou Medical University, Wenzhou 325035, China
Abstract:
OBJECTIVE To construct an ultra performance liquid chromatography-tandem quadru- pole mass spectrometry method to determine the concentration of losartan and its metabolite (E-3174) in rat plasma. METHODS An ACQUITY UPLC? BEH C18(100 mm×2.1 mm, 1.7 μm) column was used as the stationary phase at 30 ℃ on Waters XEVO TQD. The mobile phase was consisted of acetonitrile and water ( containing 0.01% formic acid and 0.05% ammonia water) (60∶40). The flow rate was 0.2 mL·min-1. Plasmas were precipitated with 200 μL acetonitrile and centrifugated at 13 000 r·min-1 for 10 min. RESULTS The retention time of E-3174 was 1.54 min. Excellent linear calibration curves of E-3174 was obtained in the concentration range of 12.5-1 600 ng·mL-1(r=0.999 6). The lower limit of quantification of E-3174 was 0.5 ng·mL-1 while the average recovery was 96.6%-98.37%. The retention time of losartan was 1.38 min and the linear calibration curves of losartan was obtained in the concentration range of 12.5-1600 ng·mL-1(r=0.999 6). The average recovery was 98.4%-100.6%. The intra and inter day relative standard deviations were<5%. There were no endogenous substances existing in the incubation system which interfered with the determination of the analyses of interest. CONCLUSION The method is accurate, simple and rapid, and suitable for the determination of losartan and its metabolite (E-3174) in rat plasma.
Key words:  CYP2C9  losartan  pharmacokinetics  UPLC-MS/MS
扫一扫关注本刊微信