• 首页期刊简介编委会刊物订阅专栏专刊电子刊学术动态联系我们English
引用本文:杨兵勋,沈春香,夏克中,孙继军,王增,陈武兵,陈立钻,楼正家,于善凯,杨芳亮,张旭峰.HPLC测定毛兰素乳液型注射液中毛兰素及有关物质含量[J].中国现代应用药学,2010,27(11):1024-1028.
.Determination of Erianin and Its Related Constituent Chrysotobibenzyl in Erianin Emulsion Injection by HPLC[J].Chin J Mod Appl Pharm(中国现代应用药学),2010,27(11):1024-1028.
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 2421次   下载 1993 本文二维码信息
码上扫一扫!
分享到: 微信 更多
HPLC测定毛兰素乳液型注射液中毛兰素及有关物质含量
杨兵勋,沈春香,夏克中,孙继军,王增,陈武兵,陈立钻,楼正家,于善凯,杨芳亮,张旭峰
作者单位
摘要:
目的 建立一种测定一类新药毛兰素乳液型注射液中毛兰素及有关物质鼓槌联苄含量的方法。方法 采用Agilent XDB C18柱(4.6 mm×250 mm,5 μm),流动相为甲醇-乙腈-水(30∶30∶40),检测波长:232 nm;流速:1.0 mL·min-1。结果 毛兰素及有关物质鼓槌联苄达到完全分离;毛兰素在5.562 5~89.0 μg·mL-1内线性关系良好(Y=13 504X+2 146.6,r=0.999 9),平均回收率100.8%;有关物质鼓槌联苄在9.292~46.462 μg·mL-1内亦有良好线性关系(Y=14.033 1X+2.388 6,r=0.999 9),平均回收率达99.8%。结论 本法灵敏,准确,专属性强,可用于测定注射液中毛兰素的含量和有关物质的检查。
关键词:  毛兰素乳液型注射液  毛兰素  有关物质  鼓槌联苄  高效液相色谱法
DOI:
分类号:
基金项目:
Determination of Erianin and Its Related Constituent Chrysotobibenzyl in Erianin Emulsion Injection by HPLC
YANG Bingxun  SHEN Chunxiang  XIA Kezhong  SUN Jijun  WANG Zeng  CHEN Wubing  CHEN Lizuan  LOU Zhengjia  YU Shankai  YANG Fangliang  ZHANG Xufeng
Abstract:
OBJECTIVE To establish an HPLC method for determining the contents of erianin and related constituent chrysotobibenzyl in Erianin emulsion injection. METHODS Agilent EclipseXDB-C18 column(4.6 mm×250 mm, 5 μm) was used. The mobile phase consisted of methanol-acetonitrile-water(30∶30∶40), the flow rate was 1.0 mL·min-1, and the detective wavelength was 232 nm. RESULTS Erianin and its related constituent chrysotobibenzyl were separated completely in Erianin emulsion injection. The calibration curves of both erianin and chrysotobibenzyl showed good linearity in the range of 5.562 5-89.0 μg·mL-1 and 9.292-46.462 μg·mL-1, respectively(erianin: Y=13 504X+2 146.6, r=0.999 9; chrysotobibenzyl: Y=14.033 1X+2.388 6, r=0.999 9). The average recovery of erianin and chrysotobibenzyl was 100.8% and 99.82%, respectively. CONCLUSION The method is accurate, sensitive and with high specific, it can be applied for determining the contents of erianin as well as its related constituent chrysotobibenzyl in Erianin emulsion injection.
Key words:  Erianin emulsion injection  erianin  related constituent  chrysotobibenzyl  HPLC