• 首页期刊简介编委会刊物订阅专栏专刊电子刊学术动态联系我们English
引用本文:程佳祎,董文彬,陈爱瑛,程敏,王军青,郑高利.微透析法测定虎杖苷的体外血浆蛋白结合率及与超滤法的比较[J].中国现代应用药学,2013,30(11):1174-1178.
CHENG Jiayi,DONG Wenbin,CHEN Aiying,CHENG Min,WANG Junqing,ZHENG Gaoli.Comparison of Microdialysis and Ultrafiltration Methods for Determination of Plasma Protein Binding Rate of Polydatin in Vitro[J].Chin J Mod Appl Pharm(中国现代应用药学),2013,30(11):1174-1178.
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 2390次   下载 1561 本文二维码信息
码上扫一扫!
分享到: 微信 更多
微透析法测定虎杖苷的体外血浆蛋白结合率及与超滤法的比较
程佳祎1, 董文彬2, 陈爱瑛2, 程敏2, 王军青2, 郑高利1,2
1.浙江中医药大学,杭州 310053;2.浙江省医学科学院,杭州 310013
摘要:
目的 采用微透析技术研究虎杖苷的体外血浆蛋白结合率,并与超滤法比较。方法 微透析探针依次浸入含虎杖苷20,60,200 μg·mL-1的大鼠、人血浆中,灌注器以2.5 μg·min-1的流速依次灌注含虎杖苷0,10,30,100,300 μg·mL-1的生理盐水,每15 min收集1次样品,HPLC分析虎杖苷浓度。以灌注液与透析液中虎杖苷的浓度差对灌注液浓度进行线性回归,计算血浆中游离虎杖苷的浓度,进而计算虎杖苷的血浆蛋白结合率,并与超滤法进行比较。结果 微透析测定虎杖苷与大鼠、人血浆蛋白结合率平均值分别为86.15%,89.08%,超滤法分别为85.60%和87.24%,两种方法结果比较接近。结论 虎杖苷与大鼠、人血浆蛋白有较高的结合率,微透析法和超滤法结果一致。
关键词:  虎杖苷  血浆蛋白结合率  微透析  超滤
DOI:
分类号:
基金项目:浙江省医学重点学科群项目(XKQ-010-001);浙江省公益技术研究社会发展项目(2011C23047)
Comparison of Microdialysis and Ultrafiltration Methods for Determination of Plasma Protein Binding Rate of Polydatin in Vitro
CHENG Jiayi1, DONG Wenbin2, CHEN Aiying2, CHENG Min2, WANG Junqing2, ZHENG Gaoli1,2
1.Zhejiang Chinese Medical University, Hangzhou 310053, China;2.Zhejiang Academy of Medical Sciences, Hangzhou 310013, China
Abstract:
OBJECTIVE The microdialysis method was used to study the plasma protein binding rate of polydatin, and the obtained results were compared with those of the conventional ultrafiltration method. METHODS The microdialysis- HPLC method was applied to dialysis the difference of concentration between dialysis fluid and perfusion fluid concentration on linear regression analysis, so the concentration of free polydatin in drug-containing plasma could be calculated, then the binding rate of polydatin with rat and human plasma can be calculated, and compared with ultrafiltration method. RESULTS The plasma protein binding rate of polydatin of rat and human plasma were about 86.15% and 89.08% respectively for microdialysis method, and were around 86.15% and 89.08% for ultrafiltration method. There was no significant difference between the two methods. CONCLUSION The binding percentage of polydatin with rat and human plasma is relative high, and results of the two methods are consistent.
Key words:  polydatin  plasma protein binding rate  microdialysis  ultrafiltration
扫一扫关注本刊微信